[Home] [Master Table of Contents]
Groundwater Investigation and Associated Source Characterization
Table 9.1-2 - Summary of Remedial Alternatives for SWMU B-3
Remedial Alternative | Contaminant Type Addressed | Data Objectives | Recommended Actions | |
VOCs | Metals | |||
Continued use of existing systems | X |
| 1a. Soil gas and respiration testing. 2a. Series of multiple configuration extraction tests (1 event) 2b. If influence cannot be determined, install VEWs to investigate non-influence areas (air emissions standard exemption must be modified in this case). 3a. Collect emissions data weekly for one month. 3b. If significant reduction in removal rates is observed, then evaluate pulsing to optimize VOC removal. | |
Expansion of existing system | X |
| 1a. Install additional soil borings based on multiple configuration testing. 1b. Collect samples and install VEW in affected soils. 1c. Design and manifold new VEWs to existing system, modify standard air exemption. 2a. Emissions testing weekly for one month. 2b. If significant reduction in removal rates is observed, then evaluate pulsing to optimize VOC removal. 3. Soil gas and respiration testing. 4a. Series of multiple configuration extraction tests (1 event). 4b. If influence cannot be determined, install VEWs to investigate non-influence areas (air emissions standard exemption must be modified in this case). | |
Excavate and treat metals "hot spots" | X |
| 1a. Perform systematic random sampling to identify "hot spots" in test soil samples for metals. 2a. Determine physical parameters. 2b. Evaluate treatment alternatives. |