[Home] [Master Table of Contents]
[Electrokinetics Table of Contents]
Electrokinetic Test Report for SWMU O-1
Table 4.3 - January 1998 System Performance Analytical Results
Sample ID | O1-A4 | O1-A4 | O1-A4/C1 | O1-A4 | O1-A4/C1 | O1-A5 | O1-A5 | O1-A5/C1 | O1-A6 | O1-A6 | O1-A6/C2 | O1-A6 | |||||
Depth (ft) | 0.0 | 2.0 | 2.0 | 4.0 | 3.0 | 0.5 | 4.0 | 4.0 | 0.5 | 2.0 | 2.0 | 4.0 | |||||
Date collected | 1/6/98 | 1/6/98 | 1/6/98 | 1/6/98 | 1/6/98 | 1/6/98 | 1/6/98 | 1/6/98 | 1/6/98 | 1/6/98 | 1/6/98 | 1/6/98 | |||||
| Comparison Criteria | Sample Analytical Results | |||||||||||||||
Constituent | Lab MDLa | Lab RL | Background (TaB)b | RRSR-GWPc | RRS2-SAIc |
|
|
|
|
|
|
|
|
|
|
|
|
VOCs, SW8260B (mg/kg): |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Tetrachloroethene | 0.0009 | 0.007 | 0.007 | 0.5 | 1.7 | 23.5 M | 697 ME | 8510 M | 1060 ME | 8410 ME | 229 M | 406 M | 1550 ME | 45.3 M | 68.6 M | 176 M | 35.6 M |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Total metals (mg/kg): |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Cadmium, SW7131A | 0.02 | 4.0 | 2.60 | 0.50 | 410 | 0.02 U | 0.18 F | 1.1 F | 0.76 F | 1.1 F | 0.02 U | 0.72 F | 0.2 F | 0.02 U | 0.02 U | 0.85 F | 0.02 U |
Chromium, SW6010A | 0.65 | 7.0 | 69.2 | 10 | 240,000 | 26.2 M | 303 ME | 1080 M | 335 ME | 1080 ME | 36.1 M | 83 M | 63 ME | 40.5 M | 43.8 M | 373 ME | 48.7 M |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Solids (%): | -- | -- | -- | -- | -- | 65.20 | 65.61 | 75.93 | 81.86 | 75.93 | 59.36 | 80.44 | 84.20 | 66.88 | 55.68 | 83.11 | 65.26 |
Sample ID | O1-C1 | O1-C1 | O1-C1 | O1-C1d | O1-C1d | O1-A1 | O1-A1 | O1-A1/C1 | O1-A1/C1 | O1-A2 | O1-A2 | O1-A2d | |||||
Depth (ft) | 0.5 | 2.0 | 4.0 | 4.0 | 4.0 | 1.5 | 3.5 | 1.5 | 3.5 | 1.5 | 3.5 | 3.5 | |||||
Date collected | 1/6/98 | 1/6/98 | 1/6/98 | 1/6/98 | 1/6/98 | 1/6/98 | 1/6/98 | 1/6/98 | 1/6/98 | 1/6/98 | 1/6/98 | 1/6/98 | |||||
| Sample Analytical Results | ||||||||||||||||
VOCs, SW8260B (mg/kg): |
|
|
|
|
|
|
|
|
|
|
|
| |||||
Tetrachloroethene | 609 ME | 510 ME | 182 M | 100 M | 108 M | 6790 ME | 4320 ME | 5090 ME | 40400 ME | 21800 ME | 8080 ME | 19400 ME | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Total Metals (mg/kg): |
|
|
|
|
|
|
|
|
|
|
|
| |||||
Cadmium, SW7131A | 0.85 F | 0.43 F | 0.68 F | 0.69 F | 0.02 U | 1.1 F | 0.68 F | 0.21 F | 2.8 F | 2.0 F | 1.3 F | 1.5 F | |||||
Chromium, SW6010A | 396 ME | 178 ME | 183 ME | 207 ME | 80.1 M | 743 ME | 200 ME | 93.7 M | 1030 ME | 746 ME | 391 ME | 510 ME | |||||
Solids (%): | 76.07 | 81.20 | 79.53 | 77.72 | 59.84 | 76.93 | 80.66 | 81.02 | 77.74 | 79.52 | 82.70 | 81.25 | |||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
Sample ID | 01-A2/C2 | 01-A2/C2 | 01-C2 | 01-C2 | 01-C2d |
|
|
|
|
|
|
| |||||
Depth (ft) | 1.5 | 3.5 | 1.5 | 3.5 | 3.5 |
|
|
|
|
|
|
| |||||
Date collected | 1/9/98 | 1/9/98 | 1/9/98 | 1/9/98 | 1/9/98 |
|
|
|
|
|
|
| |||||
Sample Analytical Results (continued) | |||||||||||||||||
VOCs, SW8260B (mg/kg): |
|
|
|
|
|
|
|
|
|
|
|
| |||||
Tetrachloroethene | 48900 ME | 3690 ME | 113 M | 243 M | 392 ME |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Total Metals (mg/kg): |
|
|
|
|
|
|
|
|
|
|
|
| |||||
Cadmium, SW7131A | 3.8 F | 0.61 F | 0.35 F | 0.02 U | 0.19 F |
|
|
|
|
|
|
| |||||
Chromium, SW6010A | 1830 ME | 109 ME | 147ME | 94.2 M | 71.6 M |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Solids (%): | 74.77 | 84.00 | 74.17 | 73.35 | 79.14 |
|
|
|
|
|
|
| |||||
Notes: a - Although MDLs were adjusted for moisture content in the analytical reports from the laboratory, they are reported as unadjusted MDLs here. b - Background values from Evaluation of Background Metals Concentrations in Soil Types at Camp Stanley Storage Activity. The site is located on soils of the Tarrant Association, gently undulating (Tab). c - Industrial risk reduction standards for groundwater protection and soil-air ingestion. d - Duplicate sample Concentrations exceeding RRS1 background levels are in bold type. Concentrations exceeding RRS2 standards are highlighted. Analysis performed by DHL Analytical Laboratory Data Qualifiers: U - The analyte was analyzed for, but not detected. The associated numerical value is at or below the MDL. F - The analyte was positively identified but the associated numerical value is below the RL. M - A matrix effect was present. E - Sample was diluted; dilution factor is presented in the raw data. |