[Home] [Master Table of Contents]

[Electrokinetics Table of Contents]

Electrokinetic Test Report for SWMU O-1

Table 2.2 - 1997 Initial Electrokinetic Location Investigation Analytical Results

Sample ID

O1-SB1

O1-SB2

OX1-97-SEW1

OX1-97-SEW2

OX1-97-SEW3 O1-EX1 O1-EX2

Dup-2d

O1-EX3

Depth (ft)

1.0

3.0

2.0

3.5

0

0

0

0

0

Date Collected

9/4/96

9/4/96

4/11/97

4/11/97

4/11/97

5/9/97

5/9/97

5/9/97

5/9/97

 

Comparison Criteria

 

Sample Analytical Results

Constituent

Lab MDL

Lab PQLa

Background (TaB)b

RRS2-GWPc

RRS2-SAIc

 

 

 

 

 

 

 

 

 

VOCs, SW8260B (mg/kg):

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tetrachloroethene

0.003

0.007

0.007

0.5

17

-

-

-

-

-

0.24

0.316

0.0277

15.6 D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total Metals (mg/kg):

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Barium, SW6010A

0.2

2.0

303.0

200

58,000

-

-

26.09 J

26.71 J

24.83 J

-

-

-

-

Cadmium, SW7131A

0.008

0.1

2.6

0.5

410

-

-

0.55

1.0

0.7

2.0

1.44

0.97

2.51

Chromium, SW6010A

0.1

7.0

69.2

10

240,000

16.50

14.32

195.8

297.84

200.34

340.51 M

164.16 M

254.31 M

783.81 M

Hex Chromium, SW7191

-

-

-

10

1,600

0.1 R

0.1 R

-

-

-

-

-

-

-

Copper, SW6010A

0.3

6.0

28.9

130

74,000

-

-

12.36 J

14.36 J

13.54 J

-

-

-

-

Lead, SW7421

0.1

0.5

105.0

1.5

1,000

-

-

8.57

13.88

10.25

-

-

-

-

Mercury, SW7471A

0.03

0.1

0.05

0.2

9.6

-

-

0.04 U

0.05 F

0.04 F

-

-

-

-

Nickel, SW6010A

0.1

15.0

44.9

200

12,000

-

-

16.85 J

20.91 J

17.28 J

-

-

-

-

Selenium, SW7740

0.25

0.5

ND

5.0

9,200

-

-

0.3 U

0.3 U

0.28 U

-

-

-

-

Silver, SW6010A

0.008

7.0

ND

51

2,800

-

-

0.38 F

0.38 F

0.37 F

-

-

-

-

Zinc, SW6010A

0.8

2.0

67.1

3,100

410,000

-

-

42.86

81.78

46.94

-

-

-

-

                             

% Solids

-

-

-

-

-

 

 

82.1

82.7

89.2

78.2

89

89.8

80.3

Note:

a: Although MDLs were adjusted for moisture content in the analytical reports from the laboratory, they are reported as unadjusted MDLs here.

b: Background values from Evaluation of Background Metals Concentrations in Soil Types at Camp Stanley Storage Activity. The site is located on soils of the Tarrant Association, gently undulating (TaB)

c: Industrial risk reduction standards for groundwater protection and soil-air ingestion

d: Duplicate Sample

Concentrations exceeding RRS1 background levels are in bold type.

Concentrations exceeding RRS2 standards are highlighted.

Analysis performed by Intertek Testing Services Environmental Laboratories

Data Qualifiers:

U: The analyte was analyzed for, but not detected. The associated numerical value is at or below the MCL.

F: The analyte was positively identified but the associated numerical value is below the RL.

M: A matrix effect was present.

E: The sample was diluted; dilution factor is presented in the raw data.