Table 2.1 - Liner Integrity Investigation Analytical Results
Sample ID | Ox1-95-SS1 | Ox1-95-SS2 | Ox1-96-SS3 | Ox1-96-SS4 | O-Pond-SP | Ox1-96-SS5 | Ox1-96-SSNW | Ox1-96-SSSW | Ox1-96-SSEW | Ox-1-96-SSCB | Ox-1-96-SSBF | Ox-1-96-SSES | |||||
Depth (ft) | 0.0 - 1.0 | 1.0 - 1.5 | 3.0 | 0 - 3.5 | 0 - 3.5 | 0 - 3.5 | 2.0 | 2.0 | 2.0 | 2.0 | 0 - 3.5 | 0 - 3.5 | |||||
Date Collected | 11/15/95 | 11/15/95 | 1/8/96 | 1/8/96 | 1/30/96 | 3/14/96 | 4/11/96 | 4/11/96 | 4/11/96 | 4/11/96 | 1/30/96 | 3/14/96 | |||||
| Comparison Criteria | Sample Analytical Results | |||||||||||||||
Constituent | Lab MDL | Lab PQLa | Background (TaB)b | RRS2-GWPc | RRS2-SAIc |
|
|
|
|
|
|
|
|
|
|
| |
VOCs, SW8260B (mg/kg): |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Tetrachloroethene | - | 0.005 | 0.007 | 0.5 | 17 | 13.8 | 25 | 80 | 1390 | 0.005 U | 0.93 | 0.005 U | 0.24 | 0.005 U | 0.005 U | 0.36 | 0.005 U |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Total Metals (mg/kg): |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Arsenic, SW6010A | 2.5 | - | 25.6 | 5.0 | 200 | 2.5 U | 2.5 U | - | - | - | - | - | - | - | - | - | - |
Barium, SW6010A | 2.5 | - | 303.0 | 200 | 58,000 | 14 | 31 | - | - | - | - | - | - | - | - | - | - |
Cadmium, SW7131A | 0.25 | - | 2.60 | 0.50 | 410 | 0.56 | 2.2 | - | - | - | - | - | - | - | - | - | - |
Chromium, SW6010A | 0.5 | - | 69.2 | 10 | 240,000 | 69 | 610 | 150 | 390 | - | - | 88 | 1300 | 400 | 300 | 130 | 210 |
Lead, SW7421 | 1.5 | - | 105.0 | 1.5 | 1000 | 8.4 | 21 | - | - | - | - | - | - | - | - | - | - |
Mercury, SW7471A | 0.1 | - | 0.05 | 0.2 | 9.6 | 0.1 U | 0.1 U | - | - | - | - | - | - | - | - | - | - |
Selenium, SW7740 | 4.0 | - | ND | 5.0 | 9,200 | 4.0 U | 4.0 U | - | - | - | - | - | - | - | - | - | - |
Silver, SW6010A | 1.0 | - | ND | 51 | 2,800 | 1.0 U | 1.0 U | - | - | - | - | - | - | - | - | - | - |
Note: a: The laboratory PQL ranged from 0.005 mg/kg to 10 mg/kg. The PQL of 0.005 mg/kg was the most consistently reported (7 of 12 total samples) b: Background values from Evaluation of Background Metals Concentrations in Soil Types at Camp Stanley Storage Activity. The site is located on soils of the Tarrant Association, gently undulating (TaB) c: Industrial risk reduction standards for groundwater protection and soil-air ingestion Concentrations exceeding RRS1 background levels are in bold type. Concentrations exceeding RRS2 standards are highlighted. Analysis performed by Chemron Incorporated Data Qualifiers: U: The analyte was analyzed for, but not detected. The associated numerical value is at or below the MDL. F: The analyte was positively identified but the associated numerical value is below the RL. M: A matrix effect was present. E: The sample was diluted; dilution factor is presented in the raw data. |