[Home] [Master Table of Contents]

Table 8 -  Offsite Groundwater VOC Results

Camp Stanley Storage Activity, Texas

 

 

Analytical

   

Bromo-dichloro-methane *

Chloroform*

Dibromo-chloro-methane *

1,1-Dichloro-ethene

cis-1,2-Dichloro-ethene

trans-1,2-Dichloro-ethene

Dichloromethane�� (methylene chloride)

Tetra-�������������� chloroethene

Trichloroethene

Vinyl chloride

1,1-Dichloro- ethane

Chloro- methane

Toluene

Well Number

Laboratory

Method

Sample Date

Dilution

(ug/L)

(ug/L)

(ug/L)

(ug/L)

(ug/L)

(ug/L)

(ug/L)

(ug/L)

(ug/L)

(ug/L)

(ug/L)

(ug/L)

(ug/L)

RFR-8

O'B&G

SW8260B

9/9/99

1:1

0.025U

0.061U

0.049U

0.144U

0.145U

0.14U

0.15F

0.087U

0.06U

0.019U

0.054U

0.073U

0.017U

RFR-3

O'B&G

SW8260B

9/9/99

1:1

0.025U

0.061U

0.049U

0.144U

0.145U

0.14U

0.17F

0.087U

0.06U

0.019U

0.054U

0.073U

0.017U

JW-30

O'B&G

SW8260B

9/9/99

1:1

0.025U

0.061U

0.049U

0.144U

0.145U

0.14U

0.15F

0.087U

0.06U

0.019U

0.054U

0.073U

0.017U

LS-7

O'B&G

SW8260

12/13/99

1:1

0.025U

0.061U

0.049U

0.144U

0.145U

0.14U

0.06U

2.51

0.3F

0.019U

0.144U

0.073U

0.017U

Comparison

MCL

--

100

100

100

7

70

100

5

5

5

2

7

--

1000

Criteria

GW-Ind

--

100

100

100

7

70

100

5

5

5

2

7

220

1000

 

Chemron2

SW8260

PQL

--

3

3

3

5

4

4

4

5

2

 
 

Chemron

SW8260

MDL

--

MDLs not provided by laboratory

 
 

ITS

SW8260A

PQL

--

0.8

0.30

0.50

0.40

1.20

0.60

0.30

1.40

1.00

 
 

ITS

SW8260A

MDL

--

0.130

0.110

0.100

0.230

0.200

0.330

0.230

0.470

0.340

 
 

DHL

SW8260B

PQL

--

NA

1.0

NA

NA

1.0

1.0

NA

1.0

1.0

 
 

DHL

SW8260B

MDL

--

NA

0.4

NA

NA

0.3

0.2

NA

0.4

0.2

 
 

O'B&G

SW8260B

RL

--

0.8

0.3

0.5

1.2

1.2

0.6

2.0

1.4

1.0

1.1

0.4

1.3

1.1

 

O'B&G

SW8260B

MDL

--

0.025

0.061

0.049

0.144

0.145

0.14

0.06

0.087

0.06

0.019

0.054

0.073

0.017

Text Box: Notes: 
  Analytes detected above laboratory  detection limits are shown in bold  font.  All well water samples were collected through well pump or via bailer.  Duplicate sample results are shown in parenthesis next to well sample results.
 - ug/L = micrograms per liter
- * Chlorination byproducts in water supply well (referenced in SWDA drinking water regulations as THMs, or trihalomethanes).  MCL for total concentration of THMs is 100 ug/L.
 - F = Laboratory data qualifier indicates the analyte was detected above the MDL but below the Practical Quantitation Limit (PQL).
- J = The analyte was positively identified below quantitation limits; the quantitation is an estimate.
- NA = Not sampled for this parameter
- R = The data are unusable with deficiencies in the ability to analyze the sample and meet criteria.

     

1 = Indicates data is screening analytical data only

Detected concentrations are in bold type.

Concentrations above the MCL have a box around them.

Shaded areas indicate analytical data analyzed by ITS Laboratories.