December 2003 Off-Post Quarterly Groundwater Monitoring Report

Section 3 - Groundwater Monitoring Analytical Results

Twenty-two wells contained VOCs at concentrations above the MDL in December 2003. Based on historical detections, the lateral extent of VOC contamination extends approximately 0.5 mile beyond the south and west boundaries of CSSA to well I10-4 to the west and LS-4 to the south. Information which includes depth of wells, pump depth, and other pertinent data necessary to properly characterize the vertical extent of migration is not readily available from most well owners.

Off-post wells are grouped by community or neighborhood for a discussion of the December 2003 results. Concentrations of VOCs detected in December 2003 are presented in Table 3.1. Full analytical results from the December 2003 sampling event are presented in Appendix B. PCE, TCE, and cis-1,2-DCE concentration trends are illustrated in Figure 3.1 for wells LS-2, LS-3, LS-6, LS-7, OFR-3, RFR-10, and RFR-11. These wells have had detections of PCE and TCE that approach and/or exceed the MCLs. Figure 3.1 also includes precipitation data from the Well CS‑MW16-LGR weather station, for evaluation of the effects of precipitation on concentrations, if any. These figures are presented prior to discussion of December 2003 groundwater sampling results for each neighborhood. Appendix C is a comparison of pre- and post-GAC concentrations detected in wells for PCE and TCE. No detections of PCE and/or TCE above the applicable MCL have occurred in the post-GAC samples collected. Further discussion of the off-post quarterly monitoring program conducted from June 2001 through September 2003 is available in the Annual Groundwater Monitoring Report, (Parsons, 2003, currently draft) and/or previous groundwater reports, located in Volume 5, Groundwater of the CSSA Environmental Encyclopedia.

Methylene chloride has been detected on- and off-post since 1992. However, for historical methylene chloride detections, methylene chloride was also present in associated quality control samples at concentrations below the RL, indicating a high likelihood that this analyte was introduced as a laboratory contaminant and was not present in the groundwater. In addition, there are no known historical uses of methylene chloride on-post, and methylene chloride has not been detected in the same wells consistently over time, supporting the conclusion that methylene chloride is present due to laboratory procedures. The earliest detection of methylene chloride was in November 1992, with sporadic detections in September 1999, December 2001, March 2002, and September 2002. Three detections of methylene chloride reported in March 2003 were flagged with a �B� flag, as the concentrations of methylene chloride were above the RL in the method blank. Methylene chloride was not detected in the June 2003, September 2003, or December 2003 sampling events.

3.1 - Fair Oaks

December 2003 Results:

In December 2003, wells FO-J1 and FO-22 were sampled in the Fair Oaks area. PCE was the only VOC detected in FO-J1, at a concentration of 0.30F �g/L, above the MDL but below the RL. This was the tenth consecutive quarterly sample collected from FO-J1. Because there was a detection, FO-J1 will remain on the quarterly sampling schedule for upcoming events. After a minimum of one year with no detections, the sampling frequency will be reviewed and possibly decreased in accordance with the Plan. Well FO-22 had no VOC detections in December 2003. No VOCs have been detected in FO-22; therefore the well will remain on an annual sampling schedule.

Results Summary:

Wells in the Fair Oaks area were first sampled in September 2001. Results for PCE, TCE, and cis-1,2-DCE from wells sampled in the Fair Oaks area during the 2003 sampling events are provided below:

Sample Date

Well ID

Concentration (�g/L)

PCE
(MCL = 5 �g/L)

TCE
(MCL = 5 �g/L)

cis-1,2-DCE
(MCL = 70 �g/L)

3/10/2003

FO-J1

ND

ND

0.20F

FO-8

ND

ND

ND

FO-17

ND

ND

ND

6/11/2003

FO-J1

0.24F

ND

ND

9/8/2003

FO-J1

0.30F

ND

ND

12/01/2003

FO-J1

0.30F

ND

ND

FO-22

ND

ND

ND

Bolded Data = Results > MDL

F = Detected above the MDL, but below the reporting limit (RL)

ND = not detected above the MDL

3.2 - Hidden Springs Estates

December 2003 Results:

In December 2003, Hidden Springs Estates well HS-2 was sampled. HS-2 had a detection of PCE at a concentration of 0.12 mg/L. This concentration was above the MDL, but below the RL. Based on this detection, HS-2 will remain on the quarterly sampling schedule in accordance with the Plan.

Results Summary:

Wells in Hidden Springs Estates were first included in CSSA�s groundwater monitoring program in December 2001. Results for PCE, TCE, and cis-1,2-DCE from the Hidden Springs area wells sampled in the 2003 sampling events are provided below:

Sample Date

Well ID

Concentration

PCE (MCL = 5 �g/L)

TCE (MCL = 5 �g/L)

cis-1,2-DCE (MCL = 70 �g/L)

3/12/2003

HS-3

0.21F

ND

ND

6/10/2003

HS-2

0.18F

ND

ND

HS-3

ND

ND

ND

9/9/2003

HS-2

0.12F

ND

ND

12/03/2003

HS-2

0.12F

ND

ND

F = Value detected above the MDL, but below the RL

ND = Not detected above the MDL

Bolded Data = Results > MDL

3.3 - I-10 Area

December 2003 Results:

Two wells were sampled in the I-10 area in December 2003: I10-2 and I10-5. Well I10-2 had no VOC detections in December 2003. Based on historical results of PCE and TCE below the RL, I10-2 will continue to be monitored on a quarterly basis in accordance with the Plan. No VOCs were detected in I10-5 in December 2003. I10-5 was first sampled in December 2002 and no VOCs were detected. I10-5 will be sampled annually in accordance with the Plan.

Results Summary:

Wells in the I-10 area were first included in CSSA�s groundwater monitoring program in September 2001. Results for PCE, TCE, and cis-1,2-DCE from I-10 area wells sampled during the 2003 sampling events are provided in the following table:

Sample Date

Well ID

Concentration (�g/L)

PCE
(MCL = 5 �g/L)

TCE
(MCL = 5 �g/L)

cis-1,2-DCE
(MCL = 70 �g/L)

3/13/2003

I10-2

0.10F

0.06F

ND

I10-4

ND

ND

ND

I10-4 (FD)

ND

ND

ND

I10-7

ND

ND

ND

I10-7 (FD)

ND

ND

ND

I10-7-NP

ND

ND

ND

 

Sample Date

Well ID

Concentration (�g/L)

PCE
(MCL = 5 �g/L)

TCE
(MCL = 5 �g/L)

cis-1,2-DCE
(MCL = 70 �g/L)

6/10/2003 to 6/12/2003

I10-2

ND

ND

ND

I10-4

ND

ND

ND

I10-7

ND

ND

ND

9/10/2003

I10-2

ND

ND

ND

I10-4

ND

ND

ND

12/2/2003

I10-2

ND

ND

ND

I10-5

ND

ND

ND

F = Value detected above the MDL, but below the RL

ND = not detected above the MDL

FD = Field Duplicate sample

Bolded Data = Results > MDL

3.4 - Jackson Woods

December 2003 Results:

In December 2003, eight Jackson Woods wells (JW-7, JW-8, JW-9, JW-14, JW-26, JW-28, JW-29, and JW‑30) were sampled. Six of the eight wells sampled had detections of COCs (JW-7, JW-8, JW-14, JW-26, JW-28, and JW-30) that do not exceed the applicable MCLs. JW-9 and JW-29 had no VOC detections; however, due to previous results that were below the RL, they will continue to be monitored on a quarterly basis in accordance with the Plan.

Well JW-7 was initially sampled in September 2003 and December 2003, and for the second time it had a detection of PCE at a concentration of 0.65 g/L, which is above the MDL but below the RL. PCE was detected below the RL (0.29 g/L) for the third consecutive sampling event of JW-8. Chloroform (53.45 g/L), bromodichloromethane (5.93 g/L), bromoform (1.07 g/L), and dibromochloromethane (2.72 g/L), were detected in JW-14. Chloroform has been consistently reported in this well since sampling began in September 2001 and all results have been below the combined trihalomethanes MCL of 80 mg/L. JW-26 had a detection of PCE (0.12 g/L, below the RL); this is the third detection of PCE below the RL since December 2002. JW-28 was sampled for the second time this quarter and toluene was detected at a concentration of 0.22 mg/L, below the RL. JW-30 had a detection of PCE (0.16 g/L, below the RL) for the third consecutive sampling event. JW-30 was sampled for the first time in December 1995, then again in September 1999. During the 1995 and 1999 sampling events, methylene chloride was the only VOC detection. Wells JW-9 and JW-29 had no VOC detections in December 2003. Wells JW-7, JW-8, JW-9, JW-14, JW-26, JW-28, JW-29, and JW-30 will remain on the quarterly sampling schedule in accordance with the Plan.

Results Summary:

Off-post sampling was first performed in the Jackson Woods area in 1995, and no VOCs were detected in the JW‑30 well sampled at that time. JW-30 was again sampled in September 1999, and methylene chloride was the only VOC detected. In March 2002, a new Jackson Woods well, JW-26, was sampled and additional wells have been added since that time. Results for PCE, TCE, and cis-1,2-DCE from wells in the Jackson Woods neighborhood sampled during the 2003 sampling events are provided below:

Sample Date

Well ID

Concentration (�g/L)

PCE
(MCL = 5 �g/L)

TCE
(MCL = 5 �g/L)

cis-1,2-DCE
(MCL = 70 �g/L)

3/10/2003 to 3/13/2003

JW-9

ND

ND

ND

JW-14

0.15F

ND

ND

JW-14-NP

0.15F

ND

ND

JW-26

0.11F

ND

ND

JW-30

ND

0.08F

0.30F

6/11/2003 to 6/18/2003

JW-6

ND

ND

ND

JW-8

0.34F

ND

ND

JW-9

ND

ND

ND

JW-13

ND

ND

ND

JW-14

ND

ND

ND

JW-26

0.14F

ND

ND

JW-27

ND

ND

ND

JW-29

0.11F

ND

ND

JW-29 (FD)

0.10F

ND

ND

JW-30

0.20F

ND

ND

9/8/2003 to 9/10/2003

JW-7

0.54F

ND

ND

JW-8

0.29F

ND

ND

JW-9

ND

ND

ND

JW-14

ND

ND

ND

JW-26

ND

ND

ND

JW-26 (FD)

ND

ND

ND

JW-28

ND

ND

ND

JW-29

ND

ND

ND

JW-30

0.20F

ND

ND

12/1/2003 to 12/4/2003

JW-7

0.65F

ND

ND

JW-8

0.29F

ND

ND

JW-9

ND

ND

ND

JW-14

ND

ND

ND

JW-26

0.12F

ND

ND

JW-28

ND

ND

ND

JW-29

ND

ND

ND

JW-30

0.16F

ND

ND

F = Value detected above the MDL, but below the RL

ND = not detected above the MDL

FD = Field Duplicate sample

Bolded Data = Results > MDL

3.5 - Leon Springs Villa

December 2003 Results:

Seven wells (LS-1, LS-2, LS-3, LS-4, LS-5, LS-6, and LS-7) in the Leon Springs Villa subdivision were sampled during the December 2003 sampling event. All of the seven wells had detections of COCs; however, none of the detections were above the applicable MCLs.

PCE was the only VOC detected in LS-1 at 0.31 mg/L, below the RL. Previously, LS-1 has also had detections of chloroform in eight consecutive events. All detections of chloroform have been below the combined trihalomethanes MCL (80 mg/L) for chloroform. PCE and TCE have been detected consistently in this well, below the RL. Well LS-1 should remain on the quarterly sampling schedule.

LS-2 had detections of PCE and TCE, at concentrations of 1.58 mg/L and 0.44 mg/L, respectively, in December 2003. The PCE concentration was above the RL and below the MCL, while the TCE concentration was above the MDL and below the RL and MCL. An evaluation of concentration trends through December 2003 for LS-2 is given in Figure 3.1. PCE concentrations doubled from September to December 2002. From December 2002 to June 2003 PCE levels decreased to below the MCL and have remained steady since. TCE concentrations have remained fairly stable since August 2001, with a slight increase from September to December 2002.

Results for LS-3 included concentrations of PCE at 1.02 mg/L and TCE at 0.11 mg/L, both below the RL. An evaluation of concentration trends through December 2003 in well LS-3 is given in Figure 3.1. The PCE concentration in LS-3 was 4.8 mg/L in September 2001, and remained above the RL (1.4 mg/L) until January 2002. PCE concentrations increased from 1.06 mg/L to 4.42 mg/L between June 2002 and December 2002. Wells LS-2 and LS-3 had a combined GAC filtration system installed by CSSA in April 2002, as described in the results section below. Based on the previous results, LS‑2 and LS-3 should be sampled quarterly in the future.

In December 2003, PCE was detected at a concentration of 0.12 mg/L in LS-4, and 0.12 mg/L in LS-4 Field Duplicate (FD) below the RL. LS-4 should continue to be sampled quarterly due to VOCs detected above the MDL.

LS-5 had a TCE detection of 0.16 mg/L in this event. The concentration was above the MDL and below the RL and MCL. TCE has been consistently detected in this well, at concentrations below the RL. Well LS-5 should remain on the quarterly sampling schedule.

In December 2003, PCE and TCE were detected at concentrations of 4.08 mg/L and 0.50 mg/L, respectively, in LS-6. TCE was below the RL. An evaluation of concentration trends in LS‑6 through December 2003 is provided in Figure 3.1. After the maximum detection of PCE at 10.0 mg/L in September 2001, PCE concentrations did not exceed the MCL again until December 2002 at 6.86 mg/L, while TCE has remained below the RL and MCL. Well LS-6 is equipped with a GAC treatment system due to past VOC concentrations. Historical results of post-GAC sampling are discussed below. Well LS-6 should continue to be sampled on a quarterly schedule.

The LS-7 sample had concentrations of PCE (3.32 mg/L), TCE (0.34 mg/L), and chloroform (0.18 mg/L) during this event. Both TCE and chloroform were below the RL, as shown by the concentration trends presented in Figure 3.1. PCE concentrations were between 1.1 mg/L and 4.6 mg/L for three years, from December 1999 through September 2002. From September 2002 to December 2002, PCE increased from 2.41 mg/L to 7.16 mg/L. The December 2002 PCE concentration was the first exceedance of the MCL (5.0 mg/L) in LS-7. Since December 2002, PCE has steadily decreased to concentrations above the RL but below the MCL. TCE concentrations in LS-7 remained below the RL (1.0mg/L) until December 2000, were it increased to just above the RL at a concentration of 1.2 mg/L. From March 2001 to September 2002 TCE concentrations dropped back below the RL, with concentrations ranging from 0.14 mg/L to 0.83 mg/L. In December 2002 the TCE concentration broke the RL for the second time at a concentration of 1.05 mg/L and has since reported concentrations below the RL. LS-7 should continue to be sampled on a quarterly schedule.

Results Summary:

Wells from the Leon Springs Villa area were first sampled in December 1999 to determine whether VOCs had migrated off-post to the south of CSSA. Based on past results for VOCs, CSSA installed GAC treatment systems at wells LS-2/LS-3, LS-6, and LS-7. Semi-annual post-GAC confirmation samples have been collected from all Leon Springs wells equipped with GAC systems (Appendix C). The samples have confirmed that the GAC units are working effectively and that VOCs are reduced to concentrations below the applicable drinking water MCLs. Chloroform was detected in post-GAC samples from LS-2/LS-3 at concentrations below the RL and MCL in September 2002, March 2003, and again in September 2003. The next post-GAC sampling event will be conducted in March 2004.

Results for PCE, TCE, and cis-1,2-DCE in pre-GAC samples collected from the Leon Springs Villa community during 2003 are provided below:

Sample Date

Well ID

Concentration (�g/L)

PCE
(MCL = 5 �g/L)

TCE
(MCL = 5 �g/L)

cis-1,2-DCE
(MCL = 70 �g/L)

3/10/2003 to 3/12/2003

LS-1

0.46F

0.12F

ND

LS-2

4.25

0.30F

ND

LS-3

3.99

0.35F

ND

LS-4

0.25F

ND

ND

LS-5

ND

0.19F

ND

LS-5 (FD)

0.08F

0.21F

ND

LS-6

4.19

0.21F

ND

LS-7

4.01

0.41F

ND

LS-7-NP

ND

ND

ND

6/9/2003 to 6/10/2003

LS-1

0.34F

0.48F

ND

LS-1 (FD)

0.39F

0.47F

ND

LS-2

2.21

0.38F

ND

LS-3

2.21

0.51F

ND

LS-4

0.20F

ND

ND

LS-5

ND

0.19F

ND

LS-6

2.73

0.23F

ND

LS-7

3.64

0.38F

ND

9/9/2003 to 9/11/2003

LS-1

0.24F

ND

ND

LS-2

2.21J

0.39F

ND

LS-2 (FD)

1.70J

0.41F

ND

LS-3

1.37F

0.14F

ND

LS-4

0.12F

ND

ND

LS-5

ND

0.20F

ND

LS-6

2.49

0.38F

ND

LS-7

3.47

0.34F

ND

12/3/2003 to 12/4/2003

LS-1

0.31F

ND

ND

LS-2

1.58

0.44F

ND

LS-3

1.02F

0.11F

ND

LS-4

0.12F

ND

ND

LS-4 FD

0.12F

ND

ND

LS-5

ND

0.16F

ND

LS-6

4.08

0.50F

ND

LS-6 FD

4.04

0.47F

ND

LS-7

3.32

0.34F

ND

F = Value detected above the MDL, but below the RL

J = The analyte was positively identified, but the quantitation is an estimation.

ND = not detected above the MDL

FD = Field Duplicate sample

Shaded data = Results >MCL

Bolded Data = Results > MDL

3.6 - Old Fredericksburg Road Area

December 2003 Results:

Three wells (OFR-1, OFR-2, and OFR-3) along Old Fredericksburg Road were sampled in December 2003. All three wells had detections of VOCs, and one well, OFR-3, exceeded applicable MCLs.

PCE was detected at 0.44 mg/L in well OFR‑1, below the RL. The results for OFR-2 indicated PCE at a concentration of 0.27 mg/L, also below the RL. These wells should continue to be monitored quarterly, in accordance with the Plan. No trend analysis was prepared for these wells because detections have not exceeded the MCL.

In December 2003, OFR-3 had detections of PCE (12.55 mg/L), TCE (7.88 mg/L), cis-1,2-DCE (0.21 mg/L), and dichlorodifluoromethane (1.53 mg/L). The PCE and TCE concentrations were above the MDL, RL, and MCL. In April 2002, a GAC unit was installed on OFR-3 due to prior PCE concentrations above the MCL. An evaluation of concentration trends in well OFR-3 through December 2003 is provided in Figure 3.1. Increases in PCE and TCE occurred from February to March 2002. PCE and TCE decreased from June 2002 to September 2002 and remained stable until June 2003. The December 2003 event showed a significant increase in the PCE and TCE concentrations, both parameters exceeding their MCLs for the third time. OFR-3 should continue to be sampled on a quarterly schedule.

Results Summary:

OFR-2 was first sampled in December 1995 to determine whether VOCs had migrated off-post to the west of CSSA. Although PCE, TCE, and cis-1,2-DCE were not detected in 1995, samples collected from OFR-3 since 2001 have contained PCE and TCE concentrations above the MCL, and TCE and cis-1,2-DCE have also been detected sporadically in the past. Every six months, post-GAC samples are collected to confirm the filtration system at OFR-3 is working. To date, no VOCs have been detected above the RLs in the post-GAC samples. The next post-GAC confirmation sample for OFR‑3 will be collected in March 2004 and results for previous post-GAC sampling events are given in Appendix C. Results for PCE, TCE, and cis-1,2-DCE from Old Fredericksburg Road area wells during the 2003 events are provided below:

Sample Date

Well ID

Concentration (�g/L)

PCE
(MCL = 5 �g/L)

TCE
(MCL = 5 �g/L)

cis-1,2-DCE
(MCL = 70 �g/L)

3/12/2003

OFR-1

0.37F

ND

ND

OFR-2

0.11F

ND

ND

OFR-3

2.81

3.25

ND

6/9/2003 to 6/12/2003

OFR-1

0.42F

ND

ND

OFR-1 (FD)

0.39F

ND

ND

OFR-2

0.19F

ND

ND

OFR-3

3.59

2.82

0.12F

OFR-4

ND

ND

ND

9/9/2003 to 9/11/2003

OFR-1

0.49F

ND

ND

OFR-2

0.26F

ND

ND

OFR-3

10.82

6.42

ND

OFR-4

ND

ND

ND

12/2/2003 to 12/4/2003

OFR-1

0.44F

ND

ND

OFR-2

0.27F

ND

ND

OFR-3

12.55

7.88

0.21F

F = Value detected above the MDL, but below the RL

ND = not detected above the MDL

FD = Field Duplicate sample

Shaded Data = Results >MCL

Bolded Data = Results > MDL

3.7 - Ralph Fair Road Area

December 2003 Results:

In December 2003, six wells (RFR-3, RFR-6, RFR-7, RFR-10, RFR-11, and RFR-12) in the Ralph Fair Road area were sampled. Of the six wells sampled, only one well, RFR-10, had detections greater than the MCL.

Well RFR-3 had a detection of PCE at a concentration of 0.12 mg/L, above the MDL and below the RL. This is the first VOC detection in this well with the exception of methylene chloride detected in September 1999. RFR-3 will be added to the quarterly sampling schedule list in accordance with the Plan.

Wells RFR-6 and RFR-7 have historically reported no VOC detections and are sampled on an annual basis. In December 2003 these wells reported no VOC detections. Both wells will remain on an annual sampling schedule.

RFR-10 concentrations exceeded the MCLs for PCE and TCE at 26.44 mg/L and 8.25 mg/L, while cis-1,2-DCE was less than the RL and MCL at a concentration of 0.96 mg/L. Chloroform was also detected at a concentration of 0.13 mg/L, below the RL. The field duplicate for RFR-10 reported similar results, PCE (30.09 mg/L), TCE (9.29 mg/L), cis-1,2-DCE (0.87 mg/L), and chloroform (0.14 mg/L). An evaluation of concentration trends through December 2003 is included in Figure 3.1. PCE concentrations decreased until March 2002 but increased from 4.50 to 14.94 mg/L from March 2002 to December 2002. From December 2002 to March 2003, the PCE concentration decreased slightly while the TCE concentration increased. In December 2003 RFR-10 exceeded its previous maximum concentration for PCE (26.44 mg/L). RFR-10 should continue to be sampled on a quarterly schedule.

In December 2003, RFR-11 had detections of PCE (0.89 mg/L below the RL) and TCE (1.73 mg/L), both of which were below the MCL. The PCE concentration was below the MCL in only three other events, June 2002, June 2003, and September 2003. TCE levels decreased from the December 2002 level of 0.67 mg/L to 0.12 mg/L in March 2003, while in recent sampling events TCE concentrations have increased. PCE levels also began to decrease from December 2002 to December 2003. Based on previous results, RFR-11 should continue to be sampled on a quarterly schedule.

Well RFR-12 had PCE and TCE detections at 0.23 �g/L and 0.18 �g/L. These values are below the RL, but above the MDL. This is only the third event with a PCE detection. TCE detections have remained steady since August 2001, above the MDL and below the RL. RFR-12 will continue to be sampled on a quarterly schedule.

Results Summary:

Ralph Fair Road wells RFR-3 and RFR-8 were sampled during the first off-post sampling performed in 1995. RFR-10 and RFR-11 required installation of GAC filtration systems in October 2001 when concentrations exceeded the MCL. Post-GAC sampling confirms that the GAC filtration systems are working effectively. See Appendix C for previous post-GAC sampling results. The next post-GAC confirmation samples will be collected in March 2004. Results for pre-GAC samples collected in 2003 for wells in the Ralph Fair Road area are provided below:

Sample Date

Well ID

Concentration (�g/L)

PCE
(MCL = 5 �g/L)

TCE
(MCL = 5 �g/L)

cis-1,2-DCE
(MCL = 70 �g/L)

3/12/2003 to 3/13/2003

RFR-10

13.88

8.37

0.31F

RFR-11

10.02

0.12

ND

RFR-12

0.10F

0.23F

ND

6/9/2003 to 6/12/2003

RFR-8

ND

ND

ND

RFR-9

ND

ND

ND

RFR-10

21.38

9.52

0.33F

RFR-11

3.06

1.17

ND

RFR-12

ND

0.24F

ND

9/8/2003 to 9/11/2003

RFR-9

ND

ND

ND

RFR-10

23.56

10.07

0.40

RFR-11

0.99

1.63

ND

RFR-12

ND

0.14

ND

12/2/2003 to 12/4/2003

RFR-3

0.12F

ND

ND

RFR-6

ND

ND

ND

RFR-7

ND

ND

ND

RFR-10

26.44

8.25

0.96F

RFR-10 FD

30.09

9.29

0.87F

RFR-11

0.89F

1.73

ND

RFR-12

0.23F

0.18F

ND

F = Value detected above the MDL, but below the RL

ND = not detected above the MDL

Shaded Data = Results >MCL

Bolded Data = Results > MDL

[Next Section]