[Home] [Master Table of Contents]
Addendum to Sampling and Analysis Plan Specific to Delivery Order DO5068
Section 4 - Constituents of Concern and Analytical Methods
In accordance with 30 TAC Chapter �335 Subchapter S, for closure under Risk Reduction Standard 1, cleanup levels shall be attained using analytical procedures taken from one of the following sources: Test Methods for Evaluating Solid Waste, EPA, SW-846, September 1994; Methods for Chemical Analysis of Water and Wastes, EPA, March 1983; or Standard Methods for the Examination of Water and Wastewater, American Public Health Association, 1995.
For all the AOC sites, the contaminants of concern are VOCs, metals, and explosives and will be analyzed using the methods listed in Table 7. Laboratory results, including PQLs, will be reported. Complete laboratory quality assurance/quality control will be kept on file in the event of a request for more information from TNRCC.
Table 7 - Constituents of Concern and Methods of Analysis for the AOC RFIs
Analyte | Method |
Volatiles | SW8260B |
Explosives | SW8330 |
Metals |
|
Arsenic | SW7060A |
Barium | SW6010B |
Cadmium | SW7131A |
Chromium | SW6010B |
Copper | SW6010B |
Lead | SW7421 |
Mercury | SW7471A |
Nickel | SW6010B |
Zinc | SW6010B |